VRF system in Bolivia starts up successfully made by DEKON

DEKON VRF SYSTEM successfully starts up in Bolivia

Though during the air delivery, we faced missing of metal parts, it is 100% caused by checking of airport transportation, but we have solved it by sending new ones to clients.

DEKON VRF SYSTEM China best factory for your project
DEKON VRF SYSTEM China best factory for your project
DEKON VRF SYSTEM China best factory for your project
DEKON VRF SYSTEM China best factory for your project

Clients request for the signal wire, we helped them to purchased in China.

DEKON VRF SYSTEM indoor and outdoor unit communication wire

After receiving the equipment, clients request the group wired controller, we send to them, without charging money in advance, but to solve the problem first.

DEKON VRF SYSTEM GROUP CONTROLLER China VRF Professional factory
DEKON VRF SYSTEM GROUP CONTROLLER China VRF Professional factory

During the starts up of the units, clients facing some errors codes and don’t know how to solve it. We send the answers by mail to help you solve all problems:

DEKON VRF SYSTEM - China VRF Professional factory
DEKON VRF SYSTEM – China VRF Professional factory

DEKON VRF SYSTEM - China VRF Professional factory

For the group controller issue, pls check below our reply:
1,Ā E038:Ā internalĀ andĀ externalĀ machineĀ communicationĀ failure.
Ā  Ā PleaseĀ checkĀ whetherĀ theĀ communicationĀ lines between insideĀ andĀ outside units inĀ accordanceĀ withĀ theĀ provisionsĀ ofĀ wiring,Ā andĀ thenĀ setĀ theĀ numberĀ of indoor units (DP09),Ā andĀ then push downĀ K2Ā /Ā K3, to find the indoor units.
2,Ā E018:Ā hostĀ andĀ slaveĀ 1Ā communicationĀ failure;
E019:Ā HostĀ andĀ slaveĀ 2Ā communicationĀ faults
HostĀ S2Ā DialĀ Code:Ā 1010
SlaveĀ –Ā S2Ā Code:Ā 0001
SlaveĀ twoĀ S2Ā dialĀ code:Ā 0010,Ā butĀ alsoĀ toĀ ensureĀ thatĀ theĀ valueĀ ofĀ SP05Ā insideĀ DP04Ā isĀ SN01;

3,Ā ifĀ thereĀ isĀ aĀ fault of the controller,Ā thenĀ thereĀ willĀ beĀ aĀ “clock”Ā icon; So, the group controller is no problem.

And the problem were solved successfully.
Again, clients facing another problem,can’t find out the indoor unit:DEKON VRF SYSTEM-China professional factory for VRF
We informed client to take off the disk on the PCB, and send us the info stored in Disk to us, and found two issues need to check and confirm:
1. System low pressure is only 2.3Kg, the requested minimum low pressure is 10kg.
Ā  Ā  It means that the freon re-charging qty is not enough.
Ā  Ā After check the total piping line length, our engineer given our suggestion of charge
to 15kg per system, and two system can not be less then 30kg freon.
2. E020 Error, it means that the outdoor unit and indoor unit is not matching.
Ā  Ā  And we send the video for checking if indoor units can be found in system.
At last, the system starts up successfully.

Clients facebook feedback about the VRF system installed from DEKON:

Start-up successful, the performance of the equipment exceeded all expectations of the customer thank you very muchĀ Ningbo Dekon Refrigeration Simon

DEKON VRF SYSTEM successfully starts up in Bolivia

QQęˆŖå›¾20170913095025

 

For HVAC products, good quality only the basic request, good services and communications counts a lot too!

All in all, your comfort air, We Dekon care!

 

 

For more info about DEKON VRF, you canĀ download our catalogĀ here:

 

For DEKON VRF Installation instructions, pls check here:

 

For other products or manuals download, pls go to

Catalog for VRF-Rooftop-Light commercial air conditioner

Catalog for Chiller, AHU, FCU

 

Contact us directly by filling the forms as below shown:

Go back

Your message has been sent

Warning
Warning
Warning
Warning

Warning.

DEKON Profesional HVAC Factory
Projects Show

Two units of centrifugal chiller start up successfully

Two units of centrifugal chiller for HILTON Hotel were started up successfully after many emails communications with clients.

 

Dear Simon.

Chiller 1 is secceed started.
1- We Charge full of 450 Kg Refrigerant R134a.
2- We are running the machine starting to cool the system.
3- Attached you can check values of operation.
From now we will track the unit operation and inform you about values and tendences to be sure the machine is operating in the right ranges and efficiencies.
dekon centrifugal chiller
dekon centrifugal chiller
dekon centrifugal chiller
dekon centrifugal chiller
dekon centrifugal chiller
dekon centrifugal chiller
dekon centrifugal chiller
dekon centrifugal chiller

 

 

Dear Simon.

Thanks for your support.

Chiller #2 was started successfully and is working fine, we are operating the unit and `preparing data to send you for analysis.

By now we are preparing to start Chiller #3 and we have the same situation as chiller # 2

1- Could you please send parameters for Chiller # 3 with “Machine Code: 122D” – See attached Picture.

2- Please check picture of panel on chiller # 3, where you can see it doesn“t appear the option By Pass in the touch screen.

Thanks and Regards

 

We are now prepare the answers to client to solve the problems soon.